Special Offer
-
Oxygen Items
Concentrator Oxygen Jay 10 Single
Model JAY-10 Flow rate 0-10L/min Purity 93±3% Outlet Pressure (Mpa) 0.04-0.07 Sound Level ≤50db Power AC220V±10%, 50/60±1Hz; AC110V±10%, 50/60±1Hz Power Consumption ≤480W Timer Present Working Time, Accumulating Time, Presetting Time from 10mins to 40hours Alarm Power failure alarm, High&Low pressure alarm Net Weight 27Kgs Size (mm) 365×375×600mm MADE IN CHINA
SKU: n/a -
Dental Homecare
Gnatus Dental Autoclave 21l
Pressure sterilization : 2.3 kgf / cm ² + / – 0.2 kgf / cm ² . Working pressure : 1.4 to 2.5 kgf / cm ³ Operating Temperature: 134 ° c . Width : 375mm Height : 360mm Power : 1200 W Weight: 46 kg Voltage : 220 V or 110 V Consumption : 0.65/1.2 kW NOTE: ohmic value RESISTANCE Resistors 127V x 12 O. Resistance 220V x 42 O. TYPE OF RESISTENCE: External strap POWER: (IMPORTANT) Fuse protection Internal plate = 2 220V-8A-1200W (10A fuse) 110/127V- 14A-1200W (15A fuse) Frequency = 50/60Hz Voltage Range = ± 2% (in tests conducted with a range of up to 10%, there was normal). GROUND CABLE Make sure that the ground wire installed on the outlet is actually connected to “earth”. Some electricians install the ground wire in the neutral (which is incorrect)
SKU: n/a -
Dental Homecare
Dental Chair Unit Gnatus G8 Fit H
Technical Specifications
Equipment Rating: According to NBR IEC 60601-1 ; Power supply voltage: 127/220 V ~ Selectable ; Frequency:50/60 Hz ; Type of protection against electric shock: First class equipment ; Degree of protection against electric shock: Type B; Operation mode: Continuous with intermittent load: T-on 1min. – T off 4min. ; Protection against water leakage: IPX0 – All chair except foot control IPX1 – foot control ; Power: 530VA ; Protection fuses: F1 and F2 T8A / 250V ; Increasing capacity: 200 Kg ; Net weight: 127 kg ; Gross weight: 160 Kg
SKU: n/a -
-
Baby Incubators
Infant Incubator with Phototherapy B-1000 GL
1.The computer servo-control box is warm; 2.In minute screen demonstration establishment temperature, box temperature, thermal rating percentage; 3.Seven functions report to the police safely: Power failure, sensor, temperature upper deviation, temperature lower deviation, box warm excess temperature, air blower and system failure;has >37the establishment function; Power failure memory, malfunction alert deafen, keyboard locking and self-checking function; 4.Double inclined plane constant temperature cover, front door wide open door, six operation windows, four solution holes, about wall cupboard, on baggage shelf; S-232 output interface.
SKU: n/a
Products Grid
Best Sellers
Recently Added
Our trusted partners
These are some of our best partners who earned a recognition for us.











